Please note: In order to keep Hive up to date and provide users with the best features, we are no longer able to fully support Internet Explorer. The site is still available to you, however some sections of the site may appear broken. We would encourage you to move to a more modern browser like Firefox, Edge or Chrome in order to experience the site fully.

Framework for Energy Neutral Treatment for the 21st Century through Energy Efficient Aeration, PDF eBook

Framework for Energy Neutral Treatment for the 21st Century through Energy Efficient Aeration PDF

Part of the WERF Research Report Series series

PDF

Please note: eBooks can only be purchased with a UK issued credit card and all our eBooks (ePub and PDF) are DRM protected.

Description

Clean and process water tests for aeration efficiency measurements were performed on a suite of diffusers in different processes for approximately one year.

The research plan was set up to test the same diffusers in different processes and different diffusers in the same process.

The most evident finding regarding the scaling factor for oxygen transfer efficiency in process water (±-factor) is that all diffusers seems to experience a decrease with time until reaching what appears a stabilization value.

As time progressed, the diffuser performance decreased for all diffusers also in terms of diffuser head loss (or dynamic wet pressure DWP).

At the same time, it was observed that once the diffuser have been colonized a relatively stable base/plateau of microbial species remains in the diffuser surface.

Regarding the DNA concentration found on the membranes, the silicone membrane tube was the less fouled than the other membrane tubes.

Although tested in different processes, the relative microbial abundance on the membrane diffusers was of the same magnitude.

One should expect much higher fouling for the high-rate process, however this may be more pronounced as the fouling biofilm fully ripens, possibly after the first year of operation.